{"product_id":"ns100-anti-sway-sensor","title":"NS100 Anti-Sway Solution for Siemens PLC","description":"\u003cp data-end=\"691\" data-start=\"424\"\u003eThe \u003cstrong data-end=\"445\" data-start=\"428\"\u003eNoswing NS100\u003c\/strong\u003e is a high-precision anti-sway sensor designed for electric overhead and gantry cranes. It continuously measures the hoist rope angle in real time, providing the critical feedback required to actively dampen load sway during travel, lifting, and lowering.\u003c\/p\u003e\n\u003cp data-end=\"879\" data-start=\"693\"\u003eThe NS100 is the core sensing component in the Noswing anti-sway system and is intended for use together with \u003cstrong data-end=\"819\" data-start=\"803\"\u003eSiemens PLCs\u003c\/strong\u003e running the \u003cstrong data-end=\"878\" data-start=\"832\"\u003eNoswing anti-sway function block\u003c\/strong\u003e. \u003c\/p\u003e\n\u003cp data-end=\"879\" data-start=\"693\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0939\/0161\/9580\/files\/NS100_Manual_EN.pdf?v=1766389776\"\u003eDownload the NS100 manual\u003c\/a\u003e\u003c\/p\u003e\n\u003chr data-end=\"884\" data-start=\"881\"\u003e\n\u003ch4 data-end=\"908\" data-start=\"886\"\u003eWhat the NS100 Does\u003c\/h4\u003e\n\u003cp data-end=\"1193\" data-start=\"910\"\u003eEvery crane movement creates natural pendulum motion in the load. The NS100 measures this motion directly at the hoist by detecting rope angle in two axes. This data allows the PLC to calculate optimal acceleration, travel speed, and deceleration ramps that actively counteract sway.\u003c\/p\u003e\n\u003cp data-end=\"1234\" data-start=\"1195\"\u003eWhen used correctly, the NS100 enables:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"1285\" data-start=\"1238\"\u003eReduced load swing during travel and stopping\u003c\/li\u003e\n\u003cli data-end=\"1319\" data-start=\"1288\"\u003eImproved positioning accuracy\u003c\/li\u003e\n\u003cli data-end=\"1343\" data-start=\"1322\"\u003eShorter cycle times\u003c\/li\u003e\n\u003cli data-end=\"1393\" data-start=\"1346\"\u003eIncreased safety and smoother crane operation\u003c\/li\u003e\n\u003cli data-end=\"1444\" data-start=\"1396\"\u003eReduced mechanical wear on the hoist and structure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1449\" data-start=\"1446\"\u003e\n\u003ch4 data-end=\"1492\" data-start=\"1451\"\u003eControl System Requirement \u003c\/h4\u003e\n\u003cp data-end=\"1577\" data-start=\"1494\"\u003e\u003cstrong data-end=\"1577\" data-start=\"1497\"\u003eThe NS100 is a sensor only. It does not perform anti-sway control by itself.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"1630\" data-start=\"1579\"\u003eTo function as intended, the following is required:\u003c\/p\u003e\n\u003cul data-end=\"1885\" data-start=\"1632\"\u003e\n\u003cli data-end=\"1649\" data-start=\"1632\"\u003e\n\u003cp data-end=\"1649\" data-start=\"1634\"\u003e\u003cstrong data-end=\"1649\" data-start=\"1634\"\u003eSiemens PLC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1792\" data-start=\"1650\"\u003e\n\u003cp data-end=\"1703\" data-start=\"1652\"\u003e\u003cstrong data-end=\"1693\" data-start=\"1652\"\u003eSiemens-based anti-sway control logic\u003c\/strong\u003e, such as:\u003c\/p\u003e\n\u003cul data-end=\"1792\" data-start=\"1706\"\u003e\n\u003cli data-end=\"1743\" data-start=\"1706\"\u003e\n\u003cp data-end=\"1743\" data-start=\"1708\"\u003eNoswing NSCore Anti-sway function blocks, or\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1792\" data-start=\"1746\"\u003e\n\u003cp data-end=\"1792\" data-start=\"1748\"\u003eSiemens-compatible anti-sway function blocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1885\" data-start=\"1793\"\u003e\n\u003cp data-end=\"1885\" data-start=\"1795\"\u003ePLC logic must actively use the rope-angle data from the NS100 to generate motion commands\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2023\" data-start=\"1887\"\u003eWithout an appropriate anti-sway function block in the PLC, the NS100 will only provide raw angle data and no sway reduction will occur.\u003c\/p\u003e\n\u003chr data-end=\"2028\" data-start=\"2025\"\u003e\n\u003ch4 data-end=\"2056\" data-start=\"2030\"\u003eCommunication Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-end=\"2094\" data-start=\"2058\"\u003e\n\u003cp data-end=\"2094\" data-start=\"2060\"\u003e\u003cstrong data-end=\"2081\" data-start=\"2060\"\u003eSensor interface:\u003c\/strong\u003e Modbus RTU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2125\" data-start=\"2095\"\u003e\n\u003cp data-end=\"2125\" data-start=\"2097\"\u003e\u003cstrong data-end=\"2116\" data-start=\"2097\"\u003ePhysical layer:\u003c\/strong\u003e RS-485\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2246\" data-start=\"2126\"\u003e\n\u003cp data-end=\"2148\" data-start=\"2128\"\u003e\u003cstrong data-end=\"2146\" data-start=\"2128\"\u003eData provided:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2176\" data-start=\"2153\"\u003eRope angle (two axes)\u003c\/li\u003e\n\u003cli data-end=\"2198\" data-start=\"2181\"\u003eAngle direction\u003c\/li\u003e\n\u003cli data-end=\"2246\" data-start=\"2203\"\u003eDynamic motion data for real-time control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2302\" data-start=\"2248\"\u003eThe NS100 communicates exclusively via \u003cstrong data-end=\"2301\" data-start=\"2287\"\u003eModbus RTU\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-end=\"2307\" data-start=\"2304\"\u003e\n\u003ch4 data-end=\"2353\" data-start=\"2309\"\u003ePROFINET Integration \u003c\/h4\u003e\n\u003cp data-end=\"2415\" data-start=\"2355\"\u003e\u003cstrong data-end=\"2415\" data-start=\"2358\"\u003eThe NS100 does NOT communicate directly via PROFINET.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"2522\" data-start=\"2417\"\u003eIf your control system is PROFINET-based, you must use a \u003cstrong data-end=\"2508\" data-start=\"2474\"\u003eModbus RTU to PROFINET gateway\u003c\/strong\u003e, for example:\u003c\/p\u003e\n\u003cul data-end=\"2587\" data-start=\"2524\"\u003e\n\u003cli data-end=\"2587\" data-start=\"2524\"\u003e\n\u003cp data-end=\"2587\" data-start=\"2526\"\u003eMOXA MGATE series or equivalent industrial protocol converter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2610\" data-start=\"2589\"\u003eThe typical setup is:\u003c\/p\u003e\n\u003cp data-end=\"2696\" data-start=\"2612\"\u003eNS100 (Modbus RTU)\u003cbr data-end=\"2633\" data-start=\"2630\"\u003e→ Modbus RTU to PROFINET converter\u003cbr data-end=\"2670\" data-start=\"2667\"\u003e→ Siemens PLC via PROFINET\u003c\/p\u003e\n\u003cp data-end=\"2813\" data-start=\"2698\"\u003eA compatible GSD file is used in Siemens TIA Portal to integrate the converter and map the NS100 data into the PLC.\u003c\/p\u003e\n\u003chr data-end=\"2818\" data-start=\"2815\"\u003e\n\u003ch4 data-end=\"2843\" data-start=\"2820\"\u003eTechnical Highlights\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-end=\"2880\" data-start=\"2847\"\u003eTwo-axis rope-angle measurement\u003c\/li\u003e\n\u003cli data-end=\"2935\" data-start=\"2883\"\u003eReal-time feedback for PLC-based anti-sway control\u003c\/li\u003e\n\u003cli data-end=\"2973\" data-start=\"2938\"\u003eModbus RTU communication (RS-485)\u003c\/li\u003e\n\u003cli data-end=\"3007\" data-start=\"2976\"\u003eIP65-rated industrial housing\u003c\/li\u003e\n\u003cli data-end=\"3051\" data-start=\"3010\"\u003eOperating temperature: –40 °C to +85 °C\u003c\/li\u003e\n\u003cli data-end=\"3095\" data-start=\"3054\"\u003eDesigned for continuous crane operation\u003c\/li\u003e\n\u003cli data-end=\"3161\" data-start=\"3098\"\u003eCompatible with Siemens TIA Portal environments (via gateway)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"3166\" data-start=\"3163\"\u003e\n\u003ch4 data-end=\"3191\" data-start=\"3168\"\u003eTypical Applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-end=\"3212\" data-start=\"3195\"\u003eOverhead cranes\u003c\/li\u003e\n\u003cli data-end=\"3230\" data-start=\"3215\"\u003eGantry cranes\u003c\/li\u003e\n\u003cli data-end=\"3263\" data-start=\"3233\"\u003eSemi-automatic crane systems\u003c\/li\u003e\n\u003cli data-end=\"3297\" data-start=\"3266\"\u003eFully automatic crane systems\u003c\/li\u003e\n\u003cli data-end=\"3356\" data-start=\"3300\"\u003eAnti-sway retrofits on Siemens-based control platforms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"3361\" data-start=\"3358\"\u003e\n\u003ch4 data-end=\"3381\" data-start=\"3363\"\u003eWhat’s Included\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-end=\"3409\" data-start=\"3385\"\u003eNS100 Anti-Sway Sensor\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAnti-sway function blocks\u003c\/li\u003e\n\u003cli\u003eModbus-to-PROFINET converter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"3441\" data-start=\"3428\"\u003eSiemens PLC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3541\" data-start=\"3507\"\u003ePLC programming or commissioning\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Noswing","offers":[{"title":"Default Title","offer_id":56125097673084,"sku":null,"price":4000.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0939\/0161\/9580\/files\/ns100-anti-sway-sensor-close-up-industrial-workbench-fulfily-0.jpg?v=1775996285","url":"https:\/\/www.noswing.shop\/products\/ns100-anti-sway-sensor","provider":"Noswing","version":"1.0","type":"link"}