{"product_id":"ns100-sensor-for-abb-acs880-integration-ready","title":"NS100 Anti-Sway Solution for ABB ACS880","description":"\u003cp data-start=\"489\" data-end=\"756\"\u003eThe \u003cstrong data-start=\"493\" data-end=\"510\"\u003eNoswing NS100\u003c\/strong\u003e is a high-precision anti-sway sensor designed for overhead and gantry cranes. It continuously measures the hoist rope angle in real time, providing the critical feedback required to actively dampen load sway during travel, lifting, and lowering.\u003c\/p\u003e\n\u003cp data-start=\"758\" data-end=\"1098\"\u003eThis version is intended for use with \u003cstrong data-start=\"796\" data-end=\"831\"\u003eABB ACS880 frequency converters\u003c\/strong\u003e, where the NS100 rope-angle feedback is used by the crane control system to generate motion commands that reduce sway. The NS100 is the core sensing component in the Noswing anti-sway ecosystem and is designed to support \u003cstrong data-start=\"1053\" data-end=\"1097\"\u003eACS880-based crane control architectures\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1216\" data-end=\"1219\"\u003e\n\u003ch4 data-start=\"1221\" data-end=\"1247\"\u003e\u003cstrong data-start=\"1224\" data-end=\"1247\"\u003eWhat the NS100 Does\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-start=\"1249\" data-end=\"1547\"\u003eEvery crane movement creates natural pendulum motion in the load. The NS100 measures this motion directly at the hoist by detecting rope angle in two axes. This feedback allows the control system to calculate optimal acceleration, travel speed, and deceleration ramps that actively counteract sway.\u003c\/p\u003e\n\u003cp data-start=\"1549\" data-end=\"1588\"\u003eWhen used correctly, the NS100 enables:\u003c\/p\u003e\n\u003cul data-start=\"1590\" data-end=\"1798\"\u003e\n\u003cli data-start=\"1590\" data-end=\"1639\"\u003e\n\u003cp data-start=\"1592\" data-end=\"1639\"\u003eReduced load swing during travel and stopping\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1640\" data-end=\"1673\"\u003e\n\u003cp data-start=\"1642\" data-end=\"1673\"\u003eImproved positioning accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1674\" data-end=\"1697\"\u003e\n\u003cp data-start=\"1676\" data-end=\"1697\"\u003eShorter cycle times\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1698\" data-end=\"1747\"\u003e\n\u003cp data-start=\"1700\" data-end=\"1747\"\u003eIncreased safety and smoother crane operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1748\" data-end=\"1798\"\u003e\n\u003cp data-start=\"1750\" data-end=\"1798\"\u003eReduced mechanical wear on hoist and structure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1800\" data-end=\"1803\"\u003e\n\u003ch4 data-start=\"1805\" data-end=\"1850\"\u003e\u003cstrong data-start=\"1808\" data-end=\"1850\"\u003eControl System Requirement \u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-start=\"1852\" data-end=\"1932\"\u003eThe NS100 is a \u003cstrong data-start=\"1867\" data-end=\"1882\"\u003esensor only\u003c\/strong\u003e. It does not perform anti-sway control by itself.\u003c\/p\u003e\n\u003cp data-start=\"1934\" data-end=\"2069\"\u003eTo function as intended, the crane control system must actively use the rope-angle feedback from the NS100 to generate motion commands.\u003c\/p\u003e\n\u003cp data-start=\"2071\" data-end=\"2109\"\u003eA typical ACS880-based setup includes:\u003c\/p\u003e\n\u003cul data-start=\"2111\" data-end=\"2383\"\u003e\n\u003cli data-start=\"2111\" data-end=\"2152\"\u003e\n\u003cp data-start=\"2113\" data-end=\"2152\"\u003e\u003cstrong data-start=\"2113\" data-end=\"2150\"\u003eABB ACS880 frequency converter(s)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2153\" data-end=\"2245\"\u003e\n\u003cp data-start=\"2155\" data-end=\"2245\"\u003eA crane control system \/ PLC logic capable of using rope-angle feedback for sway damping\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2246\" data-end=\"2383\"\u003e\n\u003cp data-start=\"2248\" data-end=\"2280\"\u003eAnti-sway control logic such as:\u003c\/p\u003e\n\u003cul data-start=\"2283\" data-end=\"2383\"\u003e\n\u003cli data-start=\"2283\" data-end=\"2324\"\u003e\n\u003cp data-start=\"2285\" data-end=\"2324\"\u003eNoswing anti-sway function blocks, or\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2327\" data-end=\"2383\"\u003e\n\u003cp data-start=\"2329\" data-end=\"2383\"\u003eControl logic designed for ACS880-based crane drives\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2385\" data-end=\"2516\"\u003eWithout an appropriate anti-sway control function, the NS100 will only provide raw angle data and \u003cstrong data-start=\"2483\" data-end=\"2515\"\u003eno sway reduction will occur\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"2518\" data-end=\"2521\"\u003e\n\u003ch4 data-start=\"2523\" data-end=\"2553\"\u003e\u003cstrong data-start=\"2526\" data-end=\"2553\"\u003eCommunication Interface\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-start=\"2555\" data-end=\"2618\"\u003e\u003cstrong data-start=\"2555\" data-end=\"2576\"\u003eSensor interface:\u003c\/strong\u003e Modbus RTU\u003cbr data-start=\"2587\" data-end=\"2590\"\u003e\u003cstrong data-start=\"2590\" data-end=\"2609\"\u003ePhysical layer:\u003c\/strong\u003e RS-485\u003c\/p\u003e\n\u003cp data-start=\"2620\" data-end=\"2638\"\u003e\u003cstrong data-start=\"2620\" data-end=\"2638\"\u003eData provided:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2639\" data-end=\"2735\"\u003e\n\u003cli data-start=\"2639\" data-end=\"2664\"\u003e\n\u003cp data-start=\"2641\" data-end=\"2664\"\u003eRope angle (two axes)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2665\" data-end=\"2684\"\u003e\n\u003cp data-start=\"2667\" data-end=\"2684\"\u003eAngle direction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2685\" data-end=\"2735\"\u003e\n\u003cp data-start=\"2687\" data-end=\"2735\"\u003eDynamic motion data for real-time sway control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2737\" data-end=\"2791\"\u003eThe NS100 communicates exclusively via \u003cstrong data-start=\"2776\" data-end=\"2790\"\u003eModbus RTU\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"2793\" data-end=\"2796\"\u003e\n\u003ch4 data-start=\"2798\" data-end=\"2839\"\u003e\u003cstrong data-start=\"2801\" data-end=\"2839\"\u003eABB ACS880 Integration \u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-start=\"2841\" data-end=\"2942\"\u003eThe NS100 does \u003cstrong data-start=\"2856\" data-end=\"2863\"\u003enot\u003c\/strong\u003e connect directly to ACS880 drives without an appropriate control architecture.\u003c\/p\u003e\n\u003cp data-start=\"2944\" data-end=\"3006\"\u003eIn ACS880-based crane systems, integration typically includes:\u003c\/p\u003e\n\u003cul data-start=\"3008\" data-end=\"3276\"\u003e\n\u003cli data-start=\"3008\" data-end=\"3097\"\u003e\n\u003cp data-start=\"3010\" data-end=\"3097\"\u003e\u003cstrong data-start=\"3010\" data-end=\"3038\"\u003eModbus RTU communication\u003c\/strong\u003e into a PLC or control system that interfaces with ACS880\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3098\" data-end=\"3181\"\u003e\n\u003cp data-start=\"3100\" data-end=\"3181\"\u003eOR a protocol gateway \/ fieldbus interface, depending on the chosen architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3182\" data-end=\"3276\"\u003e\n\u003cp data-start=\"3184\" data-end=\"3276\"\u003eDrive configuration and commissioning where the rope-angle feedback is used in control logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3278\" data-end=\"3461\"\u003eIf you are unsure about compatibility or the integration method for your crane system, contact us before ordering. We can confirm the recommended setup based on your ACS880 configuration.\u003c\/p\u003e\n\u003ch4 data-start=\"3463\" data-end=\"3557\"\u003e\n\u003cstrong data-start=\"3463\" data-end=\"3505\"\u003eNeed help verifying your ACS880 setup?\u003c\/strong\u003e\u003cbr data-start=\"3505\" data-end=\"3508\"\u003e→ \u003cem data-start=\"3510\" data-end=\"3557\"\u003eContact Noswing \/ Request compatibility check\u003c\/em\u003e\n\u003c\/h4\u003e\n\u003chr data-start=\"3559\" data-end=\"3562\"\u003e\n\u003ch4 data-start=\"3564\" data-end=\"3591\"\u003e\u003cstrong data-start=\"3567\" data-end=\"3591\"\u003eTechnical Highlights\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul data-start=\"3593\" data-end=\"3922\"\u003e\n\u003cli data-start=\"3593\" data-end=\"3628\"\u003e\n\u003ch4 data-start=\"3595\" data-end=\"3628\"\u003eTwo-axis rope-angle measurement\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3629\" data-end=\"3673\"\u003e\n\u003cp data-start=\"3631\" data-end=\"3673\"\u003eReal-time feedback for anti-sway control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3674\" data-end=\"3711\"\u003e\n\u003cp data-start=\"3676\" data-end=\"3711\"\u003eModbus RTU communication (RS-485)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3712\" data-end=\"3745\"\u003e\n\u003cp data-start=\"3714\" data-end=\"3745\"\u003eIP65-rated industrial housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3746\" data-end=\"3789\"\u003e\n\u003cp data-start=\"3748\" data-end=\"3789\"\u003eOperating temperature: –40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3790\" data-end=\"3833\"\u003e\n\u003cp data-start=\"3792\" data-end=\"3833\"\u003eDesigned for continuous crane operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3834\" data-end=\"3922\"\u003e\n\u003cp data-start=\"3836\" data-end=\"3922\"\u003eSuitable for ACS880-based crane control platforms (with correct control integration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3924\" data-end=\"3927\"\u003e\n\u003ch4 data-start=\"3929\" data-end=\"3956\"\u003e\u003cstrong data-start=\"3932\" data-end=\"3956\"\u003eTypical Applications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul data-start=\"3958\" data-end=\"4126\"\u003e\n\u003cli data-start=\"3958\" data-end=\"3977\"\u003e\n\u003cp data-start=\"3960\" data-end=\"3977\"\u003eOverhead cranes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3978\" data-end=\"3995\"\u003e\n\u003cp data-start=\"3980\" data-end=\"3995\"\u003eGantry cranes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3996\" data-end=\"4028\"\u003e\n\u003cp data-start=\"3998\" data-end=\"4028\"\u003eSemi-automatic crane systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4029\" data-end=\"4062\"\u003e\n\u003cp data-start=\"4031\" data-end=\"4062\"\u003eFully automatic crane systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4063\" data-end=\"4126\"\u003e\n\u003cp data-start=\"4065\" data-end=\"4126\"\u003eAnti-sway retrofits on ACS880-based crane control platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4128\" data-end=\"4131\"\u003e\n\u003ch4 data-start=\"4133\" data-end=\"4155\"\u003e\u003cstrong data-start=\"4136\" data-end=\"4155\"\u003eWhat’s Included\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-start=\"4157\" data-end=\"4166\"\u003eIncluded:\u003c\/p\u003e\n\u003cul data-start=\"4167\" data-end=\"4383\"\u003e\n\u003cli data-start=\"4167\" data-end=\"4193\"\u003e\n\u003cp data-start=\"4169\" data-end=\"4193\"\u003eNS100 Anti-Sway Sensor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4194\" data-end=\"4311\"\u003e\n\u003cp data-start=\"4196\" data-end=\"4311\"\u003eABB ACS880 integration documentation \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4312\" data-end=\"4383\"\u003e\n\u003cp data-start=\"4314\" data-end=\"4383\"\u003eParameter\/configuration guidance \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4385\" data-end=\"4398\"\u003eNot included:\u003c\/p\u003e\n\u003cul data-start=\"4399\" data-end=\"4534\"\u003e\n\u003cli data-start=\"4399\" data-end=\"4422\"\u003e\n\u003cp data-start=\"4401\" data-end=\"4422\"\u003eABB ACS880 drive(s)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4423\" data-end=\"4449\"\u003e\n\u003cp data-start=\"4425\" data-end=\"4449\"\u003ePLC \/ crane controller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4450\" data-end=\"4497\"\u003e\n\u003cp data-start=\"4452\" data-end=\"4497\"\u003eFieldbus \/ protocol converter (if required)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4498\" data-end=\"4534\"\u003e\n\u003cp data-start=\"4500\" data-end=\"4534\"\u003ePLC programming or commissioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4536\" data-end=\"4539\"\u003e\n\u003ch4 data-start=\"4541\" data-end=\"4562\"\u003e\u003cstrong data-start=\"4544\" data-end=\"4562\"\u003eImportant Note\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-start=\"4563\" data-end=\"4675\"\u003eIf your crane control system is not using ABB ACS880 drives, please see the standard \u003cstrong data-start=\"4639\" data-end=\"4666\"\u003eNS100 \u003c\/strong\u003einstead.\u003c\/p\u003e","brand":"Noswing","offers":[{"title":"Default Title","offer_id":56198988267900,"sku":null,"price":3500.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0939\/0161\/9580\/files\/MG_4557_1.jpg?v=1775996285","url":"https:\/\/www.noswing.shop\/products\/ns100-sensor-for-abb-acs880-integration-ready","provider":"Noswing","version":"1.0","type":"link"}